Description
Searle Condenser
SI | MDG50- 12S | |
Total Heat of Rejection | kW | 60.0 |
Ambient Temperature | °C | 30.0 |
Condensing Temperature | °C | 44.2 |
Actual TD | K | 14.2 |
Dew or Mid Point | Dew Point | |
Refrigerant | R404A | |
Hot Gas Inlet Temperature | °C | 70.0 |
Maximum Allowable Pressure | bar | 32 |
Maximum Medium Temperature | °C | 120 |
PED Category | To be confirmed | |
Sound Pressure Level | dB(A) | 33 @ 10 m |
Mean Sound Pressure Level | dB(A) | 36 @ 10 m |
Sound Power Level | dB(A) | |
Sound Spectrum 125 Hz | dB | 36 |
Sound Spectrum 250 Hz | dB | 33 |
Sound Spectrum 500 Hz | dB | 29 |
Sound Spectrum 1 kHz | dB | 29 |
Sound Spectrum 2 kHz | dB | 24 |
Sound Spectrum 4 kHz | dB | 18 |
Sound Spectrum 8 kHz | dB | 7 |
Tube/Fin Material | CU/AL | |
Surface Area | m2 | 161 |
Subcooling Section | No | |
Degrees of Subcooling | K | |
Connections | Same End | |
Inlet Connection Size | OD | 2 1/8″ |
Outlet Connection Size | OD | 1 1/8″ |
Subcooling Connections | ||
Subcooling Inlet Connection | OD | |
Subcooling Outlet Connection | OD | |
Orientation | Horizontal | |
Air Discharge Direction | Vertical | |
Refrigerant Charge | kg | 13 |
Altitude | m | 0 |
Air Volume | m3/s | 4.8 |
Internal Volume | dm3 | 40 |
Input Power (Total) | kW | 0.940 |
Energy Rating | C | |
Fan Speed | 1/min | 335 |
Control Voltage (for EC fans) | V | 0 |
Electrical Supply | 400-3-50 | |
Rows of Fans | 1 | |
Fans per Row | 2 | |
Starting Current (per fan) | A | 1.4 |
Full Load Current (per fan) | A | 1.2 |
Overall Length | mm | 2708 |
Overall Width | mm | 1158 |
Overall Height | mm | 1225 |
Dry Weight | kg | 326 |
Part Number | MDG50-12SAL | |
Software Release | 3.9.7 |